Jump to content

Acoustic impedance

From Wikipedia, the free encyclopedia
(Redirected from Specific acoustic impedance)
Sound measurements
Characteristic
Symbols
 Sound pressure p, SPL, LPA
 Particle velocity v, SVL
 Particle displacement δ
 Sound intensity I, SIL
 Sound power P, SWL, LWA
 Sound energy W
 Sound energy density w
 Sound exposure E, SEL
 Acoustic impedance Z
 Audio frequency AF
 Transmission loss TL

Acoustic impedance and specific acoustic impedance are measures of the opposition that a system presents to the acoustic flow resulting from an acoustic pressure applied to the system. The SI unit of acoustic impedance is the pascal-second per cubic metre (symbol Pa·s/m3), or in the MKS system the rayl per square metre (Rayl/m2), while that of specific acoustic impedance is the pascal-second per metre (Pa·s/m), or in the MKS system the rayl (Rayl).[1] There is a close analogy with electrical impedance, which measures the opposition that a system presents to the electric current resulting from a voltage applied to the system.

Mathematical definitions

[edit]

Acoustic impedance

[edit]

For a linear time-invariant system, the relationship between the acoustic pressure applied to the system and the resulting acoustic volume flow rate through a surface perpendicular to the direction of that pressure at its point of application is given by:[citation needed]

or equivalently by

where

  • p is the acoustic pressure;
  • Q is the acoustic volume flow rate;
  • is the convolution operator;
  • R is the acoustic resistance in the time domain;
  • G = R−1 is the acoustic conductance in the time domain (R−1 is the convolution inverse of R).

Acoustic impedance, denoted Z, is the Laplace transform, or the Fourier transform, or the analytic representation of time domain acoustic resistance:[1]

where

  • is the Laplace transform operator;
  • is the Fourier transform operator;
  • subscript "a" is the analytic representation operator;
  • Q−1 is the convolution inverse of Q.

Acoustic resistance, denoted R, and acoustic reactance, denoted X, are the real part and imaginary part of acoustic impedance respectively:[citation needed]

where

  • i is the imaginary unit;
  • in Z(s), R(s) is not the Laplace transform of the time domain acoustic resistance R(t), Z(s) is;
  • in Z(ω), R(ω) is not the Fourier transform of the time domain acoustic resistance R(t), Z(ω) is;
  • in Z(t), R(t) is the time domain acoustic resistance and X(t) is the Hilbert transform of the time domain acoustic resistance R(t), according to the definition of the analytic representation.

Inductive acoustic reactance, denoted XL, and capacitive acoustic reactance, denoted XC, are the positive part and negative part of acoustic reactance respectively:[citation needed]

Acoustic admittance, denoted Y, is the Laplace transform, or the Fourier transform, or the analytic representation of time domain acoustic conductance:[1]

where

  • Z−1 is the convolution inverse of Z;
  • p−1 is the convolution inverse of p.

Acoustic conductance, denoted G, and acoustic susceptance, denoted B, are the real part and imaginary part of acoustic admittance respectively:[citation needed]

where

  • in Y(s), G(s) is not the Laplace transform of the time domain acoustic conductance G(t), Y(s) is;
  • in Y(ω), G(ω) is not the Fourier transform of the time domain acoustic conductance G(t), Y(ω) is;
  • in Y(t), G(t) is the time domain acoustic conductance and B(t) is the Hilbert transform of the time domain acoustic conductance G(t), according to the definition of the analytic representation.

Acoustic resistance represents the energy transfer of an acoustic wave. The pressure and motion are in phase, so work is done on the medium ahead of the wave. Acoustic reactance represents the pressure that is out of phase with the motion and causes no average energy transfer.[citation needed] For example, a closed bulb connected to an organ pipe will have air moving into it and pressure, but they are out of phase so no net energy is transmitted into it. While the pressure rises, air moves in, and while it falls, it moves out, but the average pressure when the air moves in is the same as that when it moves out, so the power flows back and forth but with no time averaged energy transfer.[citation needed] A further electrical analogy is a capacitor connected across a power line: current flows through the capacitor but it is out of phase with the voltage, so no net power is transmitted into it.

Specific acoustic impedance

[edit]

For a linear time-invariant system, the relationship between the acoustic pressure applied to the system and the resulting particle velocity in the direction of that pressure at its point of application is given by

or equivalently by:

where

  • p is the acoustic pressure;
  • v is the particle velocity;
  • r is the specific acoustic resistance in the time domain;
  • g = r−1 is the specific acoustic conductance in the time domain (r−1 is the convolution inverse of r).[citation needed]

Specific acoustic impedance, denoted z is the Laplace transform, or the Fourier transform, or the analytic representation of time domain specific acoustic resistance:[1]

where v−1 is the convolution inverse of v.

Specific acoustic resistance, denoted r, and specific acoustic reactance, denoted x, are the real part and imaginary part of specific acoustic impedance respectively:[citation needed]

where

  • in z(s), r(s) is not the Laplace transform of the time domain specific acoustic resistance r(t), z(s) is;
  • in z(ω), r(ω) is not the Fourier transform of the time domain specific acoustic resistance r(t), z(ω) is;
  • in z(t), r(t) is the time domain specific acoustic resistance and x(t) is the Hilbert transform of the time domain specific acoustic resistance r(t), according to the definition of the analytic representation.

Specific inductive acoustic reactance, denoted xL, and specific capacitive acoustic reactance, denoted xC, are the positive part and negative part of specific acoustic reactance respectively:[citation needed]

Specific acoustic admittance, denoted y, is the Laplace transform, or the Fourier transform, or the analytic representation of time domain specific acoustic conductance:[1]

where

  • z−1 is the convolution inverse of z;
  • p−1 is the convolution inverse of p.

Specific acoustic conductance, denoted g, and specific acoustic susceptance, denoted b, are the real part and imaginary part of specific acoustic admittance respectively:[citation needed]

where

  • in y(s), g(s) is not the Laplace transform of the time domain acoustic conductance g(t), y(s) is;
  • in y(ω), g(ω) is not the Fourier transform of the time domain acoustic conductance g(t), y(ω) is;
  • in y(t), g(t) is the time domain acoustic conductance and b(t) is the Hilbert transform of the time domain acoustic conductance g(t), according to the definition of the analytic representation.

Specific acoustic impedance z is an intensive property of a particular medium (e.g., the z of air or water can be specified); on the other hand, acoustic impedance Z is an extensive property of a particular medium and geometry (e.g., the Z of a particular duct filled with air can be specified).[citation needed]

Acoustic ohm

[edit]

The acoustic ohm is a unit of measurement of acoustic impedance. The SI unit of pressure is the pascal and of flow is cubic metres per second, so the acoustic ohm is equal to 1 Pa·s/m3.

The acoustic ohm can be applied to fluid flow outside the domain of acoustics. For such applications a hydraulic ohm with an identical definition may be used. A hydraulic ohm measurement would be the ratio of hydraulic pressure to hydraulic volume flow.

Relationship

[edit]

For a one-dimensional wave passing through an aperture with area A, the acoustic volume flow rate Q is the volume of medium passing per second through the aperture; if the acoustic flow moves a distance dx = v dt, then the volume of medium passing through is dV = A dx, so:[citation needed]

If the wave is one-dimensional, it yields

Characteristic acoustic impedance

[edit]

Characteristic specific acoustic impedance

[edit]

The constitutive law of nondispersive linear acoustics in one dimension gives a relation between stress and strain:[1]

where

This equation is valid both for fluids and solids. In

Newton's second law applied locally in the medium gives:[2]

Combining this equation with the previous one yields the one-dimensional wave equation:

The plane waves

that are solutions of this wave equation are composed of the sum of two progressive plane waves traveling along x with the same speed and in opposite ways:[citation needed]

from which can be derived

For progressive plane waves:[citation needed]

or

Finally, the specific acoustic impedance z is

[citation needed]

The absolute value of this specific acoustic impedance is often called characteristic specific acoustic impedance and denoted z0:[1]

The equations also show that

Effect of temperature

[edit]

Temperature acts on speed of sound and mass density and thus on specific acoustic impedance.[citation needed]

Effect of temperature on properties of air
Celsius
tempe­rature
θ [°C]
Speed of
sound
c [m/s]
Density
of air
ρ [kg/m3]
Characteristic specific
acoustic impedance
z0 [Pas/m]
35 351.88 1.1455 403.2
30 349.02 1.1644 406.5
25 346.13 1.1839 409.4
20 343.21 1.2041 413.3
15 340.27 1.2250 416.9
10 337.31 1.2466 420.5
5 334.32 1.2690 424.3
0 331.30 1.2922 428.0
−5 328.25 1.3163 432.1
−10 325.18 1.3413 436.1
−15 322.07 1.3673 440.3
−20 318.94 1.3943 444.6
−25 315.77 1.4224 449.1

Characteristic acoustic impedance

[edit]

For a one dimensional wave passing through an aperture with area A, Z = z/A, so if the wave is a progressive plane wave, then:[citation needed]

The absolute value of this acoustic impedance is often called characteristic acoustic impedance and denoted Z0:[1]

and the characteristic specific acoustic impedance is

If the aperture with area A is the start of a pipe and a plane wave is sent into the pipe, the wave passing through the aperture is a progressive plane wave in the absence of reflections, and the usually reflections from the other end of the pipe, whether open or closed, are the sum of waves travelling from one end to the other.[3] (It is possible to have no reflections when the pipe is very long, because of the long time taken for the reflected waves to return, and their attenuation through losses at the pipe wall.[3]) Such reflections and resultant standing waves are very important in the design and operation of musical wind instruments.[4]

See also

[edit]

References

[edit]
  1. ^ a b c d e f g h Kinsler L, Frey A, Coppens A, Sanders J (2000). Fundamentals of Acoustics. Hoboken: Wiley. ISBN 0-471-84789-5.
  2. ^ Attenborough K, Postema M (2008). A pocket-sized introduction to acoustics. Kingston upon Hull: University of Hull. doi:10.5281/zenodo.7504060. ISBN 978-90-812588-2-1.
  3. ^ a b Rossing TD, Fletcher NH (2004). Principles of Vibration and Sound (2nd ed.). Heidelberg: Springer. ISBN 978-1-4757-3822-3. OCLC 851835364.
  4. ^ Fletcher NH, Rossing TD (1998). The physics of musical instruments (2nd ed.). Heidelberg: Springer. ISBN 978-0-387-21603-4. OCLC 883383570.
[edit]